10-7
(5) Input the password.
TR2003
OK
:MO
:/NSK ON_
N S/
SP
K
NO
(6)
:MO
:/NSK ON
NSK ON
:_
ENT
A command can be
entered only on this line
(7) The rotational position sensor calculates and writes the offset value of Home Return HO
automatically when HO/ST command is executed.
:MO
:/NSK ON
NSK ON
:HO/ST_
O /H TS
(8) Press the ENT key to execute the command.
When the “:_” colon appears on the display, Home offset HO value is automatically
calculated and set.
NSK ON
:HO/ST
HO1234
:_
ENT
(9) Input the SV command (servo-on command.)
NSK ON
:HO/ST
HO1234
:SV_
VS
(10) Press the ENT key to execute the command and thereby turn on the Motor servo.
:HO/ST
HO1234
:SV
:_
ENT
The “:_” colon appears when the Driver Unit is ready to accept another input.