— A-8 —
3  Insulation resistance of Motor winding
Caution  : Disconnect the Motor from the Driver Unit when checking insulation
resistance of Motor winding.
Caution  : Do not apply more than 500 DCV.
Figure A-10: With Cable Set
(Megohmmeter)
500V Mega
Connector Lock
Resolver Cable
Motor Cable
1
2
3
4
5
6
7
Figure A-11: Motor only
(Megohmmeter)
500V Mega
Connector Lock
Table A-7: Pins to be checked
Cable connector Motor connector
Phase A–FG
 ↔ 
(A+)    (FG)
 ↔ 
(A+)    (FG)
Phase B–FG
 ↔ 
(B+)    (FG)
 ↔ 
(B+)    (FG)
Phase C–FG
 ↔ 
(C+)    (FG)
 ↔ 
(C+)    (FG)
Phase A–B
 ↔ 
(A+)    (B+)
 ↔ 
(A+)    (B+)
Phase B–C
 ↔ 
(B+)    (C+)
 ↔ 
(B+)    (C+)
Phase C–A
 ↔ 
(C+)    (A+)
 ↔ 
(C+)    (A+)
Table A-8: Specification (For all Motor series)
Specification
With cable 1MΩ minimum
Motor only 2MΩ minimum
4  Motor and cables appearance check
l Check for Motor damage.
l Check for cable insulation.