A-10
2 Initialize Driver Unit.
1) Connect the Handy Terminal FHT11 to CN1 connector of the Driver Unit.
2) Turn on the control power only.
3) Input the password. When the colon “:” is displayed,
Press
KN S/
SP
N
ENT
O
.
4) Driver Unit echoes back “NSK ON.”
5) Input “SI/SY” command.
Press
SI /S Y
.
6) Driver Unit echoes back “INITIALIZE.” A colon “:” will be displayed to indicate completion of
initializing.
3 Input the noted parameter settings and channel programs.
1) Firstly set “PA” parameter.
l Input the password.
Press
KN S/
SP
N
ENT
O
.
Driver Unit echoes back “NSK ON.”
2) Press
A
P
ENT
(** must be the same data as noted.)
3) Set other parameters and programs accordingly.
4) Make sure that all parameters and programs are set properly.
Monitor the settings with “TS0” and “TC data” commands.
5) Turn off the power.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com