2 Initialize Driver Unit.
1) Connect the Handy Terminal FHT11 to CN1 connector of the Driver Unit.
↓
2) Turn on the control power only.
↓
3) Input the password. When the colon “:” is displayed,
Press
KN S/
SP
N
ENT
O
.
↓
4) Driver Unit echoes back “NSK ON.”
↓
5) Input “SI/SY” command.
Press
SI /S Y
.
↓
6) Driver Unit echoes back “INITIALIZE.” A colon “:” will be displayed to indicate completion of
initializing.
3 Input the noted parameter settings and channel programs.
1) Firstly set “PA” parameter.
l Input the password.
Press
KN S/
SP
N
ENT
O
.
Driver Unit echoes back “NSK ON.”
↓
2) Press
∗
A
∗
P
ENT
(** must be the same data as noted.)
↓
3) Set other parameters and programs accordingly.
↓
4) Make sure that all parameters and programs are set properly.
↓
Monitor the settings with “TS0” and “TC data” commands.
↓
5) Turn off the power.