12
(3) Connection of load line
Please connect the load line (load cable of the
parts feeder attachment) to the terminal board through
controller's cable ground. As the voltage of max
AC200V applies to this terminal, be careful of the wiring
enough. Please refer to the following note 1 when
extending the line.
Name of terminal
board
Color of wiring
1 Black 1 or Red
2 Black 2 or White
Earth bar Green/Yellow, Green or Black
*1 Please do not connect this to other than the parts
feeder. It breaks down.
*2 Please refer to P.14 when connecting the hopper
separately placed as wiring of level switch is
necessary.
*3 The connection to the controller terminal board must be
done by using the round type crimping terminal (The
terminal screw: M3).
Note 1
Extension of cable length
Please use the size of 1.0mm
2
or more when you change the cable. Moreover, when extending it to 3m or
more, please connect it to the main body cable by extending it to the vicinity of the main body by using the
cable of the size of 2.5mm
2
or more, and using the relay BOX. Extension length shall be 10m or less.
Note 2 There is a possibility that the noise is added in the power supply line. Please take measures such as
separation of the power supply from equipment which dislike noise or insertion of noise filter. Moreover,
please do not put the load line and the signal line in the same duct (protection tube).
Note 3 Correct earth shall be checked by protection continuity test machine after the earth construction work ends.
When the earth is imperfect, it is likely to get an electric shock.
* Notes for transformer usage
Please note not only the current rating but also the voltage descent due to the inrush current, etc. when you
supply power to the controller through the transformer. Please note enough the voltage descent at power
supply ON and the trouble due to the noise especially when the transformer is set commonly with other
equipment. Please consult the transformer maker about details of the problem when supplying the power to the
controller (inverter). Please refer to the paragraph of the input in P.43 for controller's inrush current. Moreover,
to reduce the influence by the noise, the use of the shielded wire or wiring of a distance as short as possible is
recommended.
負荷接続用
Earth
For connection to load
Load cable
Red
White
Green/Yellow
2
1
N
L