45850101TH Rev.1
3-34
3.4.9 Print counter display
The print counter display is used for viewing print counter values.
1. Enter the self-diagnostic mode and, until PRINTER STATUS appears, press the
[2] or [8] button (the [2] button displays the next test option and the [8] button
displays the preceding test option). Then press the [6] button.
2. Pressing the [2] or [8] button displays each count printed (pressing the [*] or [#]
button is disabled).
3. Press the [4] button to end the option (the state in step 1 is restored).
Upper Display Lower Display Format Unit Function
K-
IMPRESSIONS
******** PRINTS DEC Prints Each displays the number of
each color’s images printed.
Y-
IMPRESSIONS
******** PRINTS DEC Prints
M-
IMPRESSIONS
******** PRINTS DEC Prints
C-
IMPRESSIONS
******** PRINTS DEC Prints
TOTAL SHEET
CNT
******** PRINTS DEC Prints Displays the total number of
images printed.
*1 Tow counts apply to duplex print.
3.4.10 Factory-Shipping mode switching
The Factory-Shipping mode switching is used for switching from the Factory to Shipping
mode.
1. Enter the self-diagnostic mode and, until the following message appears, press
the [2] or [8] button.
FACTORY MODE SET
2. Press the [6] button. The following message appears. Press the [2] or [8] button
until the option to set (refer to the table shown below) appears
FACTORY MODE
SHIPPING MODE *
3. A setting for the option can be selected by pressing the [6] button with the option
on the display.
4. Press the [6] button with the setting on the display.
The setting is stored in the EEPROM. The state in step 2 is restored.
5. Repeat steps 2 through 4 when necessary.
6. Press the [4] button to end the option (the state in step 1 is restored).
Option Settings Function
FACTORY
MODE
FACTORY MODE Establishes the Factory mode (a fuse-cut
disabling mode).
SHIPPING MODE Deselects the Factory mode to enable the fuse-
cut function.
FUSE INTACT
Note:
****** is either
INTACT or
BLOWN.
BELT UNIT XXXXXX Displays the fuse status of the transfer belt unit.
FUSE UNIT XXXXXX Displays the fuse status of the fuser.