10-003591-01EN [Q7780031], Rev. 4, January 2020
Preparation for Inspection 29
3. Preparation for Inspection
In addition to the setup detailed in “Setup of Equipment” on page 23, before you
begin inspecting you must also clean the inspection surface and set up the instrument
parameters. It is recommended that you also mark the scan lines.
3.1 Drop Precautions
Be sure to observe the following precautions when handling the FlexoFORM scanner.
To prevent injury and equipment damage when operating the FlexoFORM scanner at
heights 2 meters or higher above ground or floor level, secure it with a lanyard that is
held taut (see attachment point in Figure 3-1 on page 30). Wear appropriate safety
shoes that protect your feet in case you accidentally drop the unit during handling.
Also ensure the inspection surface is free of rust, debris, or obstructions, and is
continuously ferromagnetic so that magnetic wheels remain attached to the surface.
WARNING