Use for identification” select the identification method. Possible options:
“1-wire” when performing identification with iButton key
“Omnicomm ICON” – when performing identification with Omnicomm ICON display
Identification method” select the method of identification. Possible options:
“Applyingthe identification is performed when a card or a key is applied for the
period of time specified in the parameter “Key/card identification time”.
“Retention” – identification is performed by holding the card on the reader. This
method is applied for identification via Omnicomm ICON display using the
cardholder.
Key/card identification duration” specify the time value when iButton/card key is
applied, after which will be enabled the second digital output of the terminal. Possible
values: from 0 to 60 seconds. For automatic reading of the card number, connect
Omnicomm ICON display to the terminal, switch on the readout mode and apply card.
In the “Authorized keys section press the Add key / card” button and enter the
iButton / card key numbers, which application will enable the second digital output.
The key number is indicated in 6-byte format.
For example, for a key you must enter: 000015AF6D2B
If no key/card is indicated in this section, the events will be recorded for all applied
keys/cards.
“Output activationselect “enabled” if you want to activate the second discrete
output when the iButton / card authorized key is applied.
“Output cut off delay” – specify the time after disconnecting the iButton / card key
from the readout device, after which the second digital output will be disabled.
Possible values: from 0 to 3600 seconds.
If necessary, enable/disable the sound reminder of the driver’s authorization in the