EasyManua.ls Logo

Omron C200H - Exclusive or - Xorw

Omron C200H
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
186
10 0110 0110 0110 01
15 00
01 0101 0101 0101 01
11 0111 0111 0111 01
15 00
15 00
I1
I2
R
Flags ER: Indirectly addressed DM word is non-existent. (Content of *DM word
is not BCD, or the DM area boundary has been exceeded.)
EQ: ON when the result is 0.
5-19-4 EXCLUSIVE OR – XORW(36)
I1: Input 1
IR, SR, AR, DM, HR, TC, LR, #
I2: Input 2
IR, SR, AR, DM, HR, TC, LR, #
Ladder Symbols
Operand Data Areas
R: Result word
IR, AR, DM, HR, LR
XORW(36)
I1
I2
R
@XORW(36)
I1
I2
R
When the execution condition is OFF, XORW(36) is not executed. When the
execution condition is ON, XORW(36) exclusively OR’s the contents of I1
and I2 bit-by-bit and places the result in R.
10 0110 0110 0110 01
15 00
01 0101 0101 0101 01
11 0011 0011 0011 00
15 00
15 00
I1
I2
R
Flags ER: Indirectly addressed DM word is non-existent. (Content of *DM word
is not BCD, or the DM area boundary has been exceeded.)
EQ: ON when the result is 0.
Example
Description
Example
Logic Instructions Section 5-19

Table of Contents