Power 
Supply Unit
PWR (green)
Error occurs.
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
ON
ON
CPU Unit
PWR (green)
CPU Unit
ERR (red)
CPU Unit
RDY (green)
Power 
PMAC IDE
Connectable?
ECAT LINK
(orange)
Ethernet LINK
(orange)
YES
NO
Fatal errors in the CPU Unit
Power Supply Unit 
Power supply error
CPU Unit power supply error
Hardware watchdog timer error
Initial process error
EtherCAT physical layer link not 
established
Ethernet physical layer link not 
established
DA output, DirectPWM output 
and encoder power supply from 
CK3W-AX Unit not output
Error details cannot be deter-
mined solely by checking LEDs.
*1
Non-fatal errors in the CPU Unit
Interrupted communications 
between Power PMAC IDE and 
Programmable Multi-Axis 
Controller
Analog values from CK3W-AD 
Unit not converted correctly
*1. For the details of errors that cannot be determined solely by checking the indicators, check the Sys.Status
.