EasyManua.ls Logo

Omron V430-F Series - Page 108

Omron V430-F Series
150 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Point-to-Point
It is a basic RS-232C communication protocol that does not control communication by a control
code.
Code Reader
External device
Character notation
Hex notation
Serial Trigger command
<
3C
20
>
3E
Read result
1
31
2
32
3
33
In Read Cycle
4
34
5
35
CR
0D
LF
0A
Character notation
Hex notation
Point-to-Point with XOn/XOff
With this protocol, if the free space of the Receive buffer on the side receiving data becomes small,
it sends XOff (Hex:13) to the Data Transmit side to request transmission interrupt. When it has
enough free space again, it sends XOn (Hex:11) to the Data Transmit side to request Re-transmit.
Code Reader
External device
Character notation
Hex notation
Request transmission interrupt
XOff
13
Serial Trigger command
<
3C
20
>
3E
Character notation
Hex notation
Read result
1
31
2
32
3
33
4
34
5
35
CR
0D
LF
0A
Request re-transmit
XOn
11
In Read Cycle
If XOff is received, data is not output until XOn is received.
ACK/NAK
ACK/NAK Control Codes are an RS-232C communication protocol for confirming communication.
When data is received, an ACK (Hex:06) response is sent to the device that sent the data. When
data is not successfully received, a NAK (Hex:15) response is sent to the device that sent the data.
If the device that sent the data receives a NAK response, it re-transmits its data.
When the data was successfully received:
Character notation
Hex notation
Serial Trigger command
<
3C
20
>
3E
ACK response
ACK
06
Read result
1
31
2
32
3
33
In Read Cycle
4
34
5
35
CR
0D
LF
0A
06
ACK response
ACK
Code Reader
External device
Character notation
Hex notation
When the data was not received:
NAK response
NAK
15
Read result
1
31
2
32
3
33
In Read Cycle
4
34
5
35
CR
0D
LF
0A
Read result
1
31
2
32
3
33
4
34
5
35
CR
0D
LF
0A
When NAK is received, previous Output data is re-sent.
ACK response
ACK
06
Character notatiion
Hex notatiion
Serial Trigger command
<
3C
20
>
3E
06
ACK response
ACK
Code Reader
External device
Character notatiion
Hex notatiion
5 Controlling Operation and Data Output with RS-232C
5 - 6
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings

Table of Contents

Other manuals for Omron V430-F Series

Related product manuals