Output Assembly (Legacy) Member Structure
Member Name Size (Bytes)
USER-DEFINED TAGS 4
COMMANDS 4
EXTERNAL OUTPUT 4
Total Size: 12 Bytes
Member Description
User-Defined Tags
Data set for this Member is echoed back to the USER-DEFINED TAG ECHO area of the Small Input
Assembly or the Large Input Assembly. It is used when you want to uniquely identify multiple code
readers.
Commands
An explanation of commands that can be sent to the code reader.
Bit Command
0 Trigger
1 New Master
2 - 7 Reserved
8 Disable Scanning
9 - 15 Reserved
16 Clear Read Cycle Report and Counters
17 Unlatch Outputs
18 - 31 Reserved
Trigger
Executes Read. The code reader recognizes this bit changing from 0 to 1 as the rising edge of the
trigger and its change from 1 to 0 as the falling edge of the trigger.
New Master
When this bit is ON, the next Read result is registered as the Master Symbol.
Disable Scanning
Enables / Disables Read Cycle.
0 = Read Cycle Enabled.
1 = Read Cycle Disabled. However, other commands can be executed.
Clear Read Cycle Report and Counters
Reset the Counter area from the Small or Big Input Assembly to the Read character string area to 0.
Unlatch Outputs
Turns OFF Parallel OUTPUT1, OUTPUT2, OUTPUT3 signals.
External Ouput: External Output
Turns ON Parallel OUTPUT Signal.
Bit Signal Name
0 Output 1
1 Output 2
2 Output 3
3 - 31 Reserved
Appendices
A - 31
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
A-2 EtherNet/IP Detailed Specifications
A