Section 4 Setting IP Addresses
Enter the default IP address of the Reader/Writer (192.168.1.200) in the Target IP Address Box.
Setting a Fixed IP Address
1. Enter the IP address, subnet mask, and default gateway.
2. Click the Set to the Device Button.
3. Click the Reset the Device Button to apply the IP address setting in the Reader/Writer.
(1)
(3)
(2)