Section 2 Functions
The commands that can be acknowledged by a Slave Reader/Writer are shown in the following table. If
an unsupported command is received by a Slave Reader/Writer, a multi-Reader/Writer execution error
will occur.
Name Supported?
RF Tag
communications
READ DATA No
WRITE DATA No
READ ID No
COPY DATA No
DATA FILL No
LOCK No
RF TAG OVERWRITE
COUNT CONTROL
No
RESTORE DATA No
Reader/Writer
settings
SET TAG
COMMUNICATIONS
OPTION
No
GET TAG
COMMUNICATIONS
OPTION
Ye s
SET TAG
COMMUNICATIONS
CONDITIONS
No
GET TAG
COMMUNICATIONS
CONDITIONS
Ye s
SET TCP/IP
COMMUNICATIONS
CONDITIONS
No
GET TCP/IP
COMMUNICATIONS
CONDITIONS
Ye s
SET DEVICE NAME No
GET DEVICE NAME Yes
SET WEB
COMMUNICATIONS
CONDITIONS
No
GET WEB
COMMUNICATIONS
CONDITIONS
Ye s
SET WEB PASSWORD No
GET WEB PASSWORD Yes
INITIALIZE No
Name Supported?
Checking
Reader/Writer
information
MEASURE NOISE No
GET MODEL
INFORMATION
Ye s
GET FIRMWARE VERSION Yes
GET MAC ADDRESS Yes
GET READER/WRITER
OPERATING STATUS
Ye s
GET OPERATING TIME Yes
GET RECENT ERROR
COMMAND INFORMATION
Ye s
GET COMMUNICATIONS
ERROR LOG
Ye s
GET SYSTEM ERROR LOG Yes
GET RESTORE
INFORMATION
Ye s
Reader/Writer
operation
control
STOP No
RESET No
RFID
maintenance
SET COMMUNICATIONS
DIAGNOSIS
No
GET COMMUNICATIONS
DIAGNOSIS SETTING
Ye s
Multi-Reader/
Writer
operation
SET MULTI-READER/
WRITER OPERATION
No
GET MULTI-READER/
WRITER SETTINGS
Ye s
GET MULTI-READER/
WRITER OPERATION
STATUS
Ye s