Section 2 Functions
In High-speed Traveling Mode, you can use only the READ DATA RF Tag communications command.
Also, you can specify only the Repeat communications option. If you use any communications option
other than Repeat in the High-speed Traveling Mode, an execution status error will be indicated in the
response.
Applicable RF Tag Communications Commands
Applicable Communications Options
In High-speed Traveling Mode, the Reader/Writers do not simultaneously perform communications. The Reader/Writers
individually perform communications on a time sharing basis.
Supported?
READ DATA Yes
WRITE DATA No
DATA FILL No
RF TAG OVERWRITE COUNT CONTROL No
READ ID No
COPY No
LOCK No
Supported?
Once No
Repeat Yes
FIFO Repeat No