EasyManuals Logo

Omron V680S Series User Manual

Omron V680S Series
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
Section 2 Using Multi-Reader/Writer Operation
Enabling High-speed Traveling Mode
1. Connect all of the Reader/Writers with Ethernet Cable and turn ON the power supplies.
Set a unique IP address for each Reader/Writer in advance.
Refer to Section 4 Names and Functions of Components.
2. Start a Web browser on your computer.
3. In the address field on the Web browser operation window, enter the IP address of the master Reader/
Writer (here, 192.168.1.200).
4. Display the RF Tag Communications Settings View, set the RF Tag communications option to Repeat,
and then click the Set Button.
If you specify the Once or FIFO Repeat communications option, multi-Reader/Writer operation will be enabled and a
multi-Reader/Writer execution error will occur when you restart.
http:// (IP address)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V680S Series and is the answer not in the manual?

Omron V680S Series Specifications

General IconGeneral
BrandOmron
ModelV680S Series
CategoryRfid Systems
LanguageEnglish

Related product manuals