EasyManua.ls Logo

Omron YRC - Page 217

Omron YRC
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A
Troubleshooting
A-35
9.716 : Variable data destroyed
Code : &H0009 &H02CC
Meaning/Cause
Part or all of the variable data has been destroyed.
Action
Initialize the controller.
9.717 : Program register data destroyed
Code : &H0009 &H02CD
Meaning/Cause
Part or all of the program register has been destroyed.
Action
Initialize the program.
9.718 : Communicate setting destroyed
Code : &H0009 &H02CE
Meaning/Cause
Part or all of the controller status data has been destroyed.
Action
Initialize the communication setting.
9.722 : Global EtherNet Port setting destroyed
Code : &H0009 &H02D2
Meaning/Cause
Part or all of the communication setting of general-purpose Ethernet has been destroyed.
Action
Initialize the communication setting of general-purpose Ethernet.
9.723 : Controller status data destroyed
Code : &H0009 &H02D3
Meaning/Cause
Part or all of the controller status data has been destroyed.
Action
Initialize the controller status.
9.724 : Robot status data destroyed
Code : &H0009 &H02D4
Meaning/Cause
Part or all of the robot status data has been destroyed.
Action
• Initialize the robot status.
• Reset the standard coordinates in the case of SCARA type robots.
9.725 : Axis status data destroyed
Code : &H0009 &H02D5
Meaning/Cause
Part or all of the axis status data has been destroyed.
Action
Initialize the axis status.
9.726 : Motor status data destroyed
Code : &H0009 &H02D6
Meaning/Cause
Part or all of the motor status data has been destroyed.
Action
• Initialize the motor status.
• Re-perform return-to-origin.