4. Setting the Unit (Unit Operation)
4-9
(5) Start Time (STIME)
Specifies the recording start time.
Recording starts at a specified time every day.
Setting range (Numeric input):
00:00 to 23:59
Initial value: 00:00
Note
STIME cannot be specified when STRIG is set to "OFF".
Important
Recording continues if recording has been already in progress when the specified start
time is reached.
Recording does not start if the unit is in error status when the specified start time is
reached.
(6) End Trigger (ETRIG)
Sets the recording end trigger.
The range of selection (Options):
OFF / TIME / ELPSD
Initial value: OFF
Setting Value
Operation
OFF
A long press (for 3 seconds or longer) of the SET/REC/STOP key
stops recording.
The ETRIG item appears when the key is pressed after the
setting is applied with the SET/REC/STOP key.
TIME
Recording stops when the specified end time is reached.
The STIME item appears when the key is pressed after the
setting is applied with the SET/REC/STOP key.
ELPSD
Recording stops when the specified time has elapsed after the start
of recording.
The STIME item appears when the key is pressed after the
setting is applied with the SET/REC/STOP key.
Note
A long press (for 3 seconds or longer) of the SET/REC/STOP key stops recording
overriding the TIME or ELPSD setting.

Table of Contents