F
-
4300 CLAMP
-
ON ULTRASONIC FLOW METER
ONICON Incorporated 727.447.6140 Page 78 onicon.com
APPENDIX C
-
SPEED OF SOUND IN GLYCOL WATER TABLE
GLYCOL TYPE PERCENT GLYCOL SPEED OF SOUND (ft/s) SPEED OF SOUND (m/s)
10 5052 1540
15 5167 1575
20 5282 1610
25 5364 1635
28 5413 1650
30 5446 1660
31 5449 1661
32 5456 1663
33 5463 1665
34 5466 1666
35 5472 1668
36 5476 1669
37 5482 1671
38 5485 1672
39 5492 1674
40 5495 1675
50 5545 1690
10 5013 1528
15 5089 1551
20 5167 1575
23 5236 1596
25 5282 1610
30 5348 1630
31 5354 1632
32 5361 1634
33 5367 1636
34 5374 1638
35 5381 1640
36 5394 1644
37 5407 1648
38 5420 1652
39 5433 1656
40 5446 1660
50 5528 1685