2-48
INSTALLATION ORBAN Model 8400
• Wrap lines that exceed terminal width
Uncheck:
• Append line feeds to incoming line ends
• Force incoming data to 7 bit ASCII
Leave “Line delay” and “Character delay” at their default values.
You can now type in commands described in the specification in Administra-
tive Operations, immediately below.
Administrative Operations
1. To restore factory defaults:
Command Response
RESTORE FACTORY DEFAULTS«
Are you sure (yes/no)?«
YES«
(factory defaults restored)
Restored«
NO«
(or any response other than
YES«”)
(abort)
Defaults not restored«
To protect against accidental loss of settings, you must enter the entire com-
mand string and a “yes” response in either upper- or lower case.
Restoring factory defaults does the following:
• Deletes all User Presets
• Resets all global parameters to factory default settings
• Deletes all Automation Events
• Restores Remote Interface inputs 1-8 to “no function”
• Clears all passcodes
2. To unlock an 8400/8400/PD:
The following command assigns an
All Screens passcode. This passcode is
then available from the front panel or when you connect normally via the
8400PC application (through the 8400’s Serial Port #1 or optional Ethernet
connections).
Command Response
PW ########«
(valid passcode entry)
Accepted«
(invalid passcode entry)
Denied«