2-50
INSTALLATION ORBAN Model 8400
5. To change the Modem Init string:
Applies only for modem connections (via 8400’s Serial 1 port)
Command Response
MO ATF0S0=4«
MO[ATF0S0=4] entered«
MO?
Using MO[ATF0S0=4]«
The 8400 appends CR+LF to the modem init string as transmitted to a modem
(physically connected to Serial 1). The 8400 will not perform any case conver-
sion to the argument (i.e., lower case arguments will be transmitted to the mo-
dem as lower case).
6. To change the Interface Type:
Command Response
TY M|D«
(valid argument)
Ty: Modem|Direct entered«
(invalid argument)
ERROR. Using Ty: Modem|Direct«
TY?«
Using Ty: Modem|Direct«
7. To recall a preset:
Command Response
RP XXXXXXX[PASSCODE]«
(valid passcode and preset name)
ON AIR: XXXXXXX
(invalid passcode)
ERROR: [PASSCODE] DOES NOT EXIST
(invalid preset name)
ERROR: XXXXXXX DOES NOT EXIST
In the above table:
XXXXXXX is the preset name;
PASSCODE is any valid passcode.
• If a non-existent preset name and/or an invalid passcode is entered,
the 8400 will ignore the command.
• You can apply this command anytime after the 8400 boots up. The
30-minute timeout does not apply.
• This command is useful in interfacing automation systems to the
8400.