MEWTOCOL master setting in UDP
Item
Default
Communication protocol
UDP
Action mode Client connection
Baud rate (COM1) 15200 bps/9600 bps
Note1)
Communication mode Computer link
Send type UNICAST/BROADCAST
Note2)
Destination IP address IP address of destination
Destination port No.
1025 to 32767
Source port No. 0, 1025 to 32767
Note1) Specify the same baud rate as the
communication environment setting of the
COM1 port of the FP-X.
Note2) When selecting BROADCAST, the setting of
the destination IP address is not required.
Note:
After the AFPX-COM5 is powered on, it will take about 5 seconds for initializing the Ethernet.
Until the Ethernet is initialized, data cannot be transmitted or received. For the Ethernet communication,
programming is necessary to start the communication after 5 seconds since the power turned on.
Generally, as a router does not transmit a broadcast packet, communication over the router cannot be
achieved. Using the broadcast, processing load is applied on all equipment on the network. Confirm that
the broadcast does not affect other equipment before using it.