FPΣ User's Manual 
 
7.3 High-Speed Counter Function 
115 
7.3.4.4  F167_HighSpeedCounter_Reset, Target Value Match OFF 
If the elapsed value of the high-speed counter matches the target value, an interrupt process 
immediately turns the specified output to FALSE. 
Characteristics of target value match OFF control 
1
2
4
3
0
-200
 
 
-200 Target value 
1
 
Elapsed value of high-speed counter 
2
 
Execution condition 
3
 
High-speed counter control flag 
4
 
PLC output 
 
The PLC output turns to FALSE when the elapsed value matches the target value. In addition, the high-speed 
counter control flag turns to FALSE and the instruction is deactivated. 
 
REFERENCE
 
Please refer to the FPWIN Pro online help for details and a programming 
example. 
 
7.3.5 Sample Programs 
The following programming examples demonstrate how to make control code settings and 
how to use the high-speed counter instructions. 
The FPWIN Pro projects in LD and ST code can be downloaded from the Panasonic Web site 
(
http://www.panasonic-electric-works.com/peweu/en/html/22164.php). 
The programming examples for this chapter can be found in 
pe_63403_0001_sample_high_speed.zip. 
These examples can be used with different PLC types. Therefore you have to adapt the PLC 
type in the FPWIN Pro Navigator.