FPΣ User's Manual 
 
3.6 Clock/Calendar Function 
37 
3.6.3  Sample Program for Fixed Schedule and Automatic Start 
In this example, the clock/calendar function is used to output the Y0 signal for one second at 
8:30 a.m. every day. Here, the hour/minute data stored in special data register DT90053 is 
used to output the signal at the appointed time. The value of DT90053 is written using a 
system variable. 
GVL
 
 
POU Header
 
 
LD Body
 
 
 
3.6.4  Sample Program for 30-Second Compensation 
This is a program to perform the compensation for 30 seconds when R0 turns to TRUE. If the 
30-second compensation is required, use this program. 
POU Header