FPΣ User's Manual 
 
7.4 Pulse Output Function 
133 
7.4.3.7  F175_PulseOutput_Linear, Linear Interpolation 
Pulses are output from two channels in accordance with the parameters in the specified DUT, 
so that the path to the target position forms a straight line. Pulses are output from the 
specified channel when the control flag for this channel is FALSE and the execution condition 
is TRUE. 
Pulse output characteristics 
5000
2000
y
x
 
5000 
X-axis target value (channel 0) 
2000 
Y-axis target value (channel 2) 
 
Pulses are output from channel 0 (X-axis) and channel 2 (Y-axis), so that the initial speed is 
500Hz, the target speed is 5kHz, and the acceleration/deceleration time is 300ms. The two 
axes are controlled so that a linear path is followed to the target position. 
 
REFERENCE
 
Please refer to the FPWIN Pro online help for details and a programming 
example.