Wall Mounting Procedures
1. Measure the actual space as indicated below to mark the 4 screw positions on the wall. Install 4 anchor
plugs in the wall and drive in 4 screws
(A) leaving a gap of 5 mm between the screw head and the wall.
Screw (A)
30 mm
8 mm
5 mm
Screw (A)
Screw (A)
Hammer
Anchor Plug
Drive the
screw
to this point.
463 mm
87 mm
192 mm
Installation procedure for concrete walls.
Note
• As indicated above, do not tighten the screws fully. You will tighten the screws in step 6.
• The pull-out strength of the installation area must be at least 294 N
(30 kgf) per screw.
2. Fix the Top Bracket to the left side of the PBX with 3 screws (B). (Recommended torque: 0.8 N·m
[8.2 kgf·cm] to 1.0 N·m [10.2 kgf·cm])
3. Fix the Bottom Bracket to the right side of the PBX with 3 screws (B). (Recommended torque: 0.8 N·m
[8.2 kgf·cm] to 1.0 N·m [10.2 kgf·cm])