2.3 Specifications
2.3.1 General Description
Main CPU 650 MHz Dual Core
Power Input 100 V AC to 130 V AC: 0.95 A/200 V AC to 240 V AC: 0.6 A;
50 Hz/60 Hz
Power Consumption (when fully
mounted)
50 W
(240
V: 132 VA, 200 V: 120 VA, 130 V: 104 VA, 100 V: 95 VA)
External Backup Battery External battery port is not supported.
Support UPS: USB2.0: 1 port (Connector: Type A)
Memory Backup Duration 7 years
Dialling Trunk Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling with Caller ID
(FSK/DTMF)
1600 W Maximum
Extension Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling with Caller ID
(FSK/DTMF)
SLC1 port supports PFT in combination with the LCOT1 port
connected to an analogue trunk.
Mode Conversion DP-DTMF, DTMF-DP
Ring Frequency 20 Hz/25 Hz (selectable)
Operating
Environment
Temperature 0 °C to 40 °C
Humidity 10 % to 90 % (non-condensing)
Conference Call Trunk
From 24 ´
3-party conference call to 9 ´ 8-party conference call
Music on Hold (MOH) 1 port (Level Control: -31.5 dB to +31.5 dB per 0.5 dB)
MOH: Selectable Internal/External Music Source port
External Paging 1 port (Volume Control: -15.5 dB to +15.5 dB per 0.5 dB)
Serial Interface Port RS-232C 1 (maximum 115.2 kbps)
RJ45 Port MNT Port 1 (for PC connection) 10BASE-T/100BASE-TX/
1000BASE-T (Auto MDI/
MDI-X)
LAN Port 1 (for LAN connection)
WAN Port 1 (for WAN connection)
Extension Connection Cable SLT 1-pair wire (T, R)
Air-cooling method FAN
Dimension
430 mm (W) ´ 88 mm (H) ´ 340 mm (D)
Weight (when fully mounted) Under 5.1 kg