9.1List of parameters
9-27
No.
Title
Unit
Range
Size
[byte]
Function/Contents
Attribute
Related
control
mode
Reference
98
Function expansion
setup 4
-
-2147483648
to
2147483647
4
Sets various function in bit units:
R
All
-
bit0-2:
For manufacture use.
Permanently set at 0.
bit3:
Effective bit setting of
Multi-turn data.
0:16bit
1: 9bit
bit4 to 7:
For manufacture use.
Permanently set at 0.
bit8:
Control mode switching
function expansion
0: Conventional specification
1: hm operation expansion
specification
bit9 to 19:
For manufacture use.
Please set fixed to 0
bit20:
Mechanical brake circuit
overload protection function
0: Valid1
1: Invalid
bit21 to 31:
For manufacture use.
Permanently set at 0.
bit 0 is the least significant bit.
101
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-