Chapter 4Settings — [PROJECTOR SETUP] menu
ENGLISH - 179
[ANGLE MONITOR] screen
Displays the tilt angle of the projector graphically based on the angle information detected by the built-in angle
sensor.
1) Press the <ENTER> button while 5/6 page of the [STATUS] screen is displayed.
f The [ANGLE MONITOR] screen is displayed.
-10
-20
-30 -150
+150
-160
+160
-170
+170+10
+20
+30
-170
-160
-150 -30
+30
-20
+20
-10
+10+170
+160
+150
+ 20°
-
20°
ANGLE MONITOR
ZERO CALIBRATION
RETURN
RESET
2) Press the <ENTER> button or the <DEFAULT> button.
f The angle benchmark will switch each time you press the button.
<ENTER> button Displays the angle of the zero calibration state representing the current installation attitude of the projector
<DEFAULT> button
Displays the angle of the zero calibration reset state.
Resets the zero calibration and displays the detection result of the angle sensor as it is.
Note
f The illustration of the projector in the [ANGLE MONITOR] screen does not rotate and does not follow the attitude change of the projector.
f The illustration of the projector shows the monitor of the roll angle and the monitor of the pitch angle.
g The rear view illustration of the projector(left side): indicates the roll angle
g The side view illustration of the projector(right side): indicates the pitch angle
f The green line intersecting the illustration of the projector indicates the angle to the benchmark selected in step 2). Read the left and right
gauges.
f The red wq mark on the horizontal axis represents the benchmark surface (0°, +180°) selected in step 2).
f The values shown at the top of of the roll angle monitor and the pitch angle monitor are common with the values displayed in [ROLL ANGLE]
and [PITCH ANGLE] on the [STATUS] screen.
f The benchmark selected in step 2) remains unchanged even if the main power is turned o󰀨 and on.
f [ANGLE MONITOR] screen can be displayed directly by pressing the <FUNCTION> button when [PROJECTOR SETUP] menu
[FUNCTION BUTTON] is set to [ANGLE MONITOR].
[INDICATOR SETTING]
Set the indicator‑o󰀨 function that allows the projector can be used without the indicators (power indicator <ON (G)/
STANDBY (R)>, light source indicator <LIGHT1> / <LIGHT2>, temperature indicator <TEMP>) lit or blink even
when the projector is in standby mode or projection mode.
1) Press as to select [INDICATOR SETTING].
2) Press the <ENTER> button.
f The warning message of the indicator‑o󰀨 function is displayed.
3) Press the <ENTER> button.
f The [INDICATOR SETTING] screen is displayed.
4) Press as to select [INDICATOR MODE].