Chapter 5 Operations — Using the web control function
236 - ENGLISH
Note
f The generated self-signed certicate can be deleted by clicking [Certicate] → [Self-signed Certicate] → [Delete].
However, it cannot be deleted when [HTTPS set up] → [Connection] is set to [HTTPS]. Delete it after changing the setting to perform the
HTTP communication.
[HTTPS set up] page
Set this page when HTTPS (Hypertext Transfer Protocol Secure) communication encrypted with the SSL/TLS
protocol is to be performed between the computer and the projector while the web control function is used.
Click [Detailed set up] → [HTTPS set up].
To perform the HTTPS communication, it is necessary to install the certicate for authentication into the projector
in advance. For details of installing the certicate, refer to “[Certicate] page” (x page 230).
1
2
3
1 [Connection]
Sets the connection method to the projector.
f [HTTP]: Uses the HTTP communication. (Factory default
setting)
f [HTTPS]: Uses the HTTPS communication.
2 [HTTPS port]
Sets the port number to be used with the HTTPS
communication.
Allowed port number: 1 to 65535
Factory default setting: 443
3 [Set]
Enables the setting.
Note
f When the [Connection] setting is changed from [HTTPS] to [HTTP], the screen may not be displayed when the operation or update of the
web control screen is performed. In such case, delete the cache of the web browser.
[Crestron Connected] page
Set the information required for connecting the control system of Crestron Electronics, Inc. to the projector, and
the information to monitor/control the projector using the control system of Crestron Electronics, Inc.
When the [NETWORK] menu → [NETWORK CONTROL] → [Crestron Connected
TM
] is set to [OFF], the [Crestron
Connected] page cannot be set.
Click [Detailed set up] → [Crestron Connected].