6.4. Self-Diagnostic Mode
6.5. Self-Diagnostic Error Code Table
Self-Diagnostic Function (Refer Section 6.4. Self-Diagnostic Mode) provides information on any problems occurring for the unit and
its respective components by displaying the error codes. These error code such as U**, H** and F** are stored in memory and held
unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
6.5.1. Power Supply Error Code Table
FL Display
Key Operation
Front Key
Item
DescriptionMode Name
Self Diagnostic
Mode
To enter into self diagnostic checking Step 1: Select CD mode
(Ensure no disc is inserted).
To exit, press [8] on main unit or
remote control.
Step 2: Press & hold [g] button
follow by [y/i] on
main unit for 2 seconds.
Error Code
Information
System will perform a check on
any unusual/error code from the
memory
Example: Step 1: In self diagnostic mode,
Press [g] on main unit.
To exit, press [8] on main unit or
remote control.
Delete error code To clear the stored in memory
(EEPROM IC)
Step 1: In self diagnostic mode,
Press [0] on remote control
for more than 5 seconds.
FL Display
Key Operation
Front Key
Item
DescriptionMode Name
Error Code F61 Diagnosis Contents:
Power Amp IC output abnormal.
Upon power on, PCONT=HIGH,
DC_DET_AMP after checking LSI.
Error Code F76 Diagnosis Contents:
Power Amp IC output abnormal.
DC_DET_PWR.
Error Code
F61-76
Diagnosis Contents:
Power Amp IC output abnormal.
Both DCDET (NG).
Press [g] on main unit for next
error.
Press [g] on main unit for next
error.
Press [g] on main unit for next
error.