Chapter 5 THE KEYPAD
The 650V can be fitted with a Keypad (Man-
Machine Interface, MMI).
It provides for local control of the drive,
monitoring, and complete access for
application programming a connection to a pc
is required along with the drive software tool.
Insert the Keypad into the front of the drive
(replacing the blank cover and plugging into
the RS232 programming port); or mount it up
to 3 metres away using the optional mounting
kit with connecting lead: refer to Chapter 3:
“Installing the Drive” – Fitting the Remote
6521 Keypad.
The Power-Up Condition
On initial power-up, direct from the factory,
the drive is in Local Control and the MMI
will display the Local Setpoint,
.
All parameters will be at factory default
settings. Any changes to these conditions are
automatically saved. The drive will initialise
on subsequent power-ups with the previously saved settings and control mode.
Using the Keypad
Control Key Definitions
Escape
Navigation
– Displays the previous level’s menu
Parameter
– Returns to the parameter list
Trip Display
– Removes Trip or Error message from display
allowing investigation of parameters
Menu
Navigation
– Displays the next menu level, or the first
parameter of the current Menu
Parameter
–
Moves cursor to the left when the parameter is
adjustable
Increment
Navigation
– Move upwards through the menu system
Parameter
– Increase value of the displayed parameter
Local Mode
– Increase value of the local setpoint
Decrement
Navigation
– Move down through the menu system
Parameter
– Decrease value of the displayed parameter
Local Mode
– Decrease value of the local setpoint
Run
Local Mode
– Run the drive
Trip Reset
– Resets trip condition allowing drive to resume
operation
Stop
Local Mode
– Stops the drive. Trip Reset in all modes
Navigation –
Press and hold to toggle between Local and
Remote Control modes (refer to page 5-4)
Trip Reset
– Resets trip condition allowing drive to resume
operation
Programming Keys
Local
Key
Control
Local
Key
Control
The 6521 Keypad