9-8  Technical Specifications
 
650V AC Drive 
Electrical Ratings (400V Build Variant) 
Power Supply =  380-460V ±10%, 50/60Hz 
5% 
Motor power, output current and input current must not be exceeded under steady state 
operating conditions.  
Catalog Number 
(North America) 
Maximum 
Switching 
Frequency 
(kHz) 
(Output Overload Motoring 110% for 30s)
650V-432160C    11kW  23  26.1  300  350  3  4000 
  650V/0010/460/..  15Hp  21  22.1  280  320  3  4000 
650V-432230C    15kW  30  33.6  440  500  3  4000 
   650V/0015/460/..  20Hp  27  28.5  410  470  3  4000 
650V-432300C    18.5kW  37  44  550  610  3  6000 
  650V/0020C/460/..  25Hp  34  38  530  580  3  6000 
FRAME D : 
Input currents for kW ratings are at 400V 50Hz ac input and for Hp ratings at 460V 60Hz ac 
input. Prospective short circuit current 10kA. 
* For UL Listed products rated at 30kW/40Hp, a supply voltage of 460V is required. The higher 
current ratings are applicable to non UL applications only. 
(Output Overload Motoring 150% for 30s, 180% for 0.5s short term rating)
650V-432310D    15kW  31  34.8  420  480  3  4000 
  650V/0020/460/..  20Hp  31  28.5  400  460  3  4000 
650V-432380D    18.5kW  38  40.5  545  605  3  6000 
  650V/0025/460/..  25Hp  38  34.2  515  575  3  6000 
650V-432450D    22kW  45  47.2  670  730  3  6000 
  650V/0030/460/..  30Hp  45  40  640  700  3  6000 
650V-432590D    30kW  59  66  760  860  3  15000 
  650V/0040D/460/..  40Hp  52  56  740  830  3  15000 
(Output Overload Motoring 110% for 30s)
650V-432310D    18.5kW  38  40.5  545  605  3  4000 
  650V/0020/460/..  25Hp  38  34.2  515  575  3  4000 
650V-432380D    22kW  45  47.2  670  730  3  6000 
  650V/0025/460/..  30Hp  45  40  640  700  3  6000 
650V-432450D    30kW  59  61  760  860  3  6000 
  650V/0030/460/..  40Hp  52  51  740  830  3  6000 
650V-432590D    37kW  73  84  920  1030  3  15000 
  650V/0040D/460/..  50Hp  65  68  890  980  3  15000