6-18 Programming Your Application
650V AC Drive
** Power Dependent Defaults
These parameters (marked with “**” in function block descriptions and Application diagrams)
are set to a value depending on the drive's overall “power-build” indicated by the Product Code.
We recommend that you do not change the Product Code.
230V Build Power Dependent Defaults
Frame C
Frame D
Parameter
Function Block
Tag
5.5kW
7.5kW
11kW
15kW
18.5kW
POWER MOTOR DATA 1158 5.50 kw 7.50 kw 11.00 kw 15.00 kw 18.50 kw
MOTOR CURRENT MOTOR DATA 64 19.65 A 25.39 A 34.78 A 46.96 A 57.16 A
MAG CURRENT MOTOR DATA 65 5.90 A 7.62 A 10.43 A 14.09 A 17.15 A
NAMEPLATE RPM MOTOR DATA 83 1445.0 RPM 1450.0 RPM 1460.0 RPM 1470.0 RPM 1470.0 RPM
MOTOR VOLTAGE MOTOR DATA 1160 230.0 V 230.0 V 230.0 V 230.0 V 230.0 V
POWER FACTOR MOTOR DATA 242 0.80 0.83 0.86 0.87 0.87
STATOR RES MOTOR DATA 119 0.4505
ohms
0.3487
ohms
0.2545 ohms 0.1885 ohms 0.1543
ohms
LEAKAGE INDUC MOTOR DATA 120 14.34 mH 11.10 mH 8.10 mH 6.00 mH 4.91 mH
MUTUAL INDUC MOTOR DATA 121 57.36 mH 44.39 mH 32.41 mH 24.00 mH 19.64 mH
ROTOR TIME CONST MOTOR DATA 1163 276.04 ms 303.65 ms 379.56 ms 506.08 ms 506.08 ms
BRAKE POWER DYNAMIC BRAKING 78 0.1kw 0.1 kw 0.1 kw 0.1 kw 0.1 kw
FREQUENCY INJ BRAKING 577 9.0 Hz 9.0 Hz 9.0 Hz 9.0 Hz 9.0 Hz
DEFLUX TIME INJ BRAKING 710 0.5 s 0.5 s 1.0 s 1.0 s 1.0 s
BASE VOLTS INJ BRAKING 739 100.00% 100.00% 100.00% 100.00% 100.00%
DC LEVEL INJ BRAKING 581 2.50% 2.50% 1.80% 1.80% 1.80%
DC PULSE INJ BRAKING 579 2.0 s 2.0 s 2.0 s 2.0 s 2.0 s
FINAL DC PULSE INJ BRAKING 580 1.0 s 1.0 s 3.0 s 3.0 s 3.0 s
FIXED BOOST FLUXING 107 0.00% 0.00% 0.00% 0.00% 0.00%
ACCEL TIME REFERENCE RAMP 258 10.0 s 10.0 s 10.0 s 10.0 s 10.0 s
DECEL TIME REFERENCE RAMP 259 10.0 s 10.0 s 10.0 s 10.0 s 10.0 s
DEFLUX DELAY PATTERN GEN 100 2.0 s 2.0 s 3.0 s 3.0 s 3.0 s
SEARCH VOLTS FLYCATCHING 573 9.00% 9.00% 9.00% 9.00% 9.00%
SEARCH BOOST FLYCATCHING 32 40.00% 40.00% 15.00% 15.00% 15.00%
SEARCH TIME FLYCATCHING 574 10.0 s 10.0 s 15.0 s 15.0 s 15.0 s
REFLUX TIME FLYCATCHING 709 3.0 s 3.0 s 4.0 s 4.0 s 4.0 s
OVERLOAD MOTOR DATA 1164 2.0 2.0 2.0 2.0 2.0
SPEED PROP GAIN SPEED LOOP 1187 20.00 20.00 20.00 20.00 20.00
SPEED INT TIME SPEED LOOP 1188 100 ms 100 ms 100 ms 100 ms 100 ms
MOTOR CONNECTION MOTOR DATA 124 1 : STAR 1 : STAR 1 : STAR 1 : STAR 1 : STAR
BRAKE RESISTANCE DYNAMIC BRAKING 77 100 100 100 100 100
BOOST MODE FLUXING 1058 0 0 0 0 0

Table of Contents