5-4  The Keypad
 
650V AC Drive 
How To Change a Parameter Value 
•  View the parameter to be edited and press 
 
to display the parameter’s value.  
•  Select the digit to be changed (pressing the 
 
key moves the cursor from right to left).  
•  Use the 
 
 keys to adjust the value. Hold the key momentarily to adjust the value 
marginally, or hold the key to make rapid changes; the rate of change varies with the time 
held. 
•  Press 
 to return to the parameter display. The new value is stored. 
Special Menu Features 
Resetting to Factory Defaults (2-button reset) 
Power-up the drive whilst holding the keys as 
shown to return to factory default settings. 
This loads Application 1. Then press the 
 
key. 
Selecting Local or Remote Control 
The drive can operate in one of two ways: 
Remote Control:  Allowing access for application programming using digital and 
analog inputs and outputs 
Local Control:  Providing local control and monitoring of the drive using the 
Keypad  
Local control keys are inactive when Remote Control is selected. 
In Remote Control, the drive uses a remote setpoint. In Local Control, it uses the Local Setpoint 
parameter whose value is adjusted on the MMI. 
Note: 
You can only change between Local and Remote Control when the drive is “stopped”, 
and either 
 or the Local Setpoint is displayed. 
Remote to Local Control: 
Local to Remote Control: 
 
Note: 
For safety reasons, the drive will not return to Remote Control if this will cause the drive 
to start. Check RUN and JOG inputs are low. 
Hold down the keys opposite:
Power-up the drive, continue
to hold for at least 1 second
HOLD
Hold this key down until
the display shows 
REMOTE
LOCAL
Hold this key down until
the display spells 
Release the key to display
the Local Setpoint
REMOTE
LOCAL
View the Local Setpoint
Hold this key down until
is removed from the display
Release the key to display