6-12 Programming Your Application
650V AC Drive
MMI Parameters Table
APPLICATION
LOCK
F
Setting this parameter to TRUE prevents editing of
parameter
P
1.
Set this parameter to FALSE to edit parameter
P
1.
0=FALSE
1=TRUE
0
DETAILED MENUS
Selects Full menu detail when TRUE. The additional
parameters in the Full menus are indicated in this
table by F
0=FALSE
1=TRUE
0
ENC MODE
F
Set this parameter to the requirements for your
encoder:
0 : QUADRATURE (using digital inputs 6 & 7,
ENCA and ENCB respectively)
1 : CLOCK/DIR (using digital inputs 6 & 7,
ENCA and ENCB respectively)
2 : CLOCK (using digital input 6, ENCA)
0= QUADRATURE
1= CLOCK/DIR
2= CLOCK
0
ENC RESET
F
When TRUE the POSITION and SPEED
outputs are set (and held) at zero.
0=FALSE
1=TRUE
0
ENC INVERT
F
When TRUE, changes the sign of the
measured speed and the direction of the
position count.
0=FALSE
1=TRUE
0
ENC LINES
F
The number of lines must be set to match the
type of encoder being used. Incorrect setting
of this parameter will result in an erroneous
speed measurement.
100 to 10000 100
ENC SPEED
SCALE
F
This parameter allows the output "speed" to
be scaled to any value the user requires. With
a default value of 1.00, the output "speed" is
measured in revs per second. Changing the
ENC SPEED SCALE value to 60.00 will
provide an output in revs per minute.
To provide an output in percent of the motor
maximum speed, where maximum speed is
the maximum speed your motor will run in
rpm, the ENC SPEED SCALE parameter
should be set to the result of:
0.00 to 300.00 1.00
ENC SPEED
F
Speed feedback, in units defined by the ENC
SPEED SCALE parameter.
—.x —.x