Technical Specifications 9-5
650V AC Drive
Cabling Requirements for EMC Compliance
External AC
Supply EMC
Filter to Drive
Cable
Cable Type
(for EMC Compliance)
Unscreened Screened/
armoured
Screened/
armoured
Screened/
armoured
Screened
From all
other wiring
(clean)
From all other wiring (noisy) From all other wiring
(sensitive)
Length Limitations
With External AC Supply
EMC Filter
Unlimited 50 metres 0.3 metres 25 metres
25 metres
Screen to Earth
Connection
Both ends Both ends Both ends Drive end only
300 metres
maximum
* Maximum motor cable length under any circumstances
Cooling Fans
The forced-vent cooling of the drive is achieved by 1, or in some cases 2 fans. The Fan Rating
gives the volume of air venting from the drive. All except the Frame F fans are internally-
supplied 24V fans.
650V-232280C.. 650V/0010/.. 25cfm (42.5 m³/hr)
650V-432230C & 650V-432300C 650V/0015/.. & 650V/0020C/.. 35cfm (59.5 m³/hr)
650V-232540D, 650V-232680D & 650V-432450D 650V/0020/.., 650V/0025/.. & 650V/0030/.. 55cfm (93.4 m³/hr)
650V-432590D 650V/0040/.. 81cfm (138 m³/hr)
All models All models 160cfm (272 m³/hr)
One single phase fan is provided, supplied from an auxiliary input. There are two voltage variants, either 115V ac or
220Vac. The fan is powered from a single phase supply which uses a capacitor to generate the quadrature phase. Protect
the fan using a 3A fuse.
110/120V : 130W, 10µF, Stator - 16Ω
220/240V : 140W, 2.5µF, Stator - 62Ω
All models All models 270cfm (459 m³/hr)