Function
Code
Function Denition Setting Range Mfr’s Value Change
F500 -
F580
Multi-Stage speed control
denition table, refer to
product manual
N/A N/A X
Function
Code
Function Denition Setting Range Mfr’s Value Change
F600
DC Braking Function
Selection
0: Disabled;
1: Braking before
starting;
2: Braking during
stopping;
3: Braking during
starting and
stopping
0 X
F601
Initial Frequency for DC
Braking
0.20-50.00 1.00 √
F602
DC Braking level before
Starting (V/A)
0-100 10 √
F603
DC Braking level During Stop
(V/A)
0-100 10 √
F604
Braking Lasting Time Before
Starting (S)
0.00-30.00 0.50 √
F605
Braking Lasting Time During
Stopping (S)
0.00-30.00 0.50 √
F606 Reserved
F607 Stall Adjustment Function
0: Disabled;
1: Enabled
2: Reserved
3: Voltage current
control
4: Voltage control
5: Current control
0 √
Parameter List and Default Settings
10-12