Chapter 1. Installation
9
OFF
1
OFF
2
ON
OFF
3
ON
OFF
4
ON
OFF
5
ON
OFF OFF
67
OFF
8
RESERVED
ALIGNMENT MODE
COMMUTATION TEST MODE
HALL SELECT
TACH SCALING
RESERVED
Off
No
Yes
No
Yes
Resolver Mode (All APEX Motors: 610 - 640)
Hall Mode
One speed resolver (1V = 1,000 RPM with a one speed resolver) (All APEX Motors: 610 - 640)
Two speed resolver (1V = 1,000 RPM with a two speed resolver)
All Off
OFF
ON
OFF
ON
OFF
ON
OFF
ON
CONTINUOUS CURRENT (peak of sine wave)
PEAK CURRENT
MOTOR THERMAL TIME CONSTANT
5 amps
7
9
11
13
15
17
20 (APEX610 - 640)
15 amps
18
22
25
29
32
36
40 (APEX610 - 640)
10 minutes
20 (APEX610)
30 (APEX620, 630)
40 (APEX635, 640)
OFF
OFF
OFF
312
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
645
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
87
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
1234567812345678
SW 118SW 218SW 318OFF
APEX6154
DIPs
OFF
OFF
OFF
45
ON
ON
ON
OFF
ON
OFF
OFF
OFF
78
ON
ON
ON
OFF
ON
OFF
6
ON
RESERVED
POLE PAIR NUMBER
RESOLVER SPEED
CURRENT LOOP COMPENSATION (motor inductance)
Off
2 (APEX610 - 630)
3 (APEX635, 640)
Reserved
Reserved
1 (All APEX Motors: 610 - 640)
2
25 – 40 mH
5 – 15 mH (APEX610)
15 – 25 mH (APEX620, 630, 635, 640)
Reserved
OFF
3
REGEN FAULT
HALL DEGREES
Enable
Disable
120° Hall motor
60° Hall motor
OFF
ON
OFF
ON
1
2
12345678
APEX610
123456781234567812345678
SW 118 SW 318SW 218OFF
APEX620 & APEX630
123456781234567812345678
SW 118 SW 318SW 218OFF
APEX635 & APEX640
123456781234567812345678
SW 118 SW 318SW 218OFF
DEFAULT SETTINGS:
The default setting for all DIP switches
when the APEX6154 ships from the factory is OFF..
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com