Command Reference 8-91
Sense Command Subsystem
n
Sense Subsystem Command Tree
[:SENSe]
:ACQuisition
:APERture
8
<meas time> | MIN | MAX
:HOFF
[:STATe]
8
ON | OFF
:MODE
8
TIME
:TIME
8
<numeric value> | MIN | MAX
:AUTO
8
ONCE
:FREQuency
:BURSt
:APERture 8
<numeric value> | MIN | MAX
:STARt
:DELay
8
<numeric value> | MIN | MAX
:SYNC
:PERiod
8
<numeric value> | MIN | MAX
:PREScaler
[:STATe]
8
ON | OFF
:POWer
:UNIT *
8
DBM | W
:RANGe
:LOWer
8
<Miinimum frequency for autotrigger> | MIN | MAX
:REGRession
8
ON | OFF | AUTO
:FUNCtion
8
‘Measuring function [ Primary channel [ , Secondary channel ] ]
:HF
:ACQuisition
[:STATe] *
8
<boolean>
:FREQuency
:CENTer *
8
<numeric value>
:ROSCillator
:SOURce
8
INTernal | EXTernal
:TIError
:FREQuency
8
<numeric value>
:AUTO
8
ON | OFF
:TINTerval
:AUTO
8
ON | OFF
:TOTalize
:GATE
[:STATe]
8
ON | OFF
* CNT-90XL only

Table of Contents

Other manuals for Pendulum CNT-90 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pendulum CNT-90 Series and is the answer not in the manual?

Pendulum CNT-90 Series Specifications

General IconGeneral
BrandPendulum
ModelCNT-90 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals