Installation and commissioning
24
8.02 Commissioning
Check the machine, especially the electrical leads, for any damage
Before commissioning the machine, remove grommet 1 of oil container 2.
Grommet 1 is only needed for support during transportation and must not be
used while the machine is in operation.
Clean the machine thoroughly and oil it (see chapter 11 Care and maintenance).
Connect the machine to the compressed air supply. When it is connected, the gauge
should show a pressure of approx. 6 bar. If necessary, have this reading correctly set
(see Chapter 11.04, Checking / adjusting the air pressure).
Have skilled personnel check if the machine can be operated with the available mains
voltage.
Do not operate the machine if there is any discrepancy.
The machine may only be connected to an earthed socket!
When the machine is running, the balance wheel must turn towards the operator. If this
is not the case, have the motor adjusted by specialist staff, see Chapter 12.12 Parameter
settings.
8.03 Switching the machine on/off
Switch the machine on (see Chapter 7.01, On/off switch).
●
●
●
●
●
●
●
Fig. 8 - 04 Fig. 8 - 05
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
3
1
2