Adjustment
80
12.08 Adjusting the automatic presser foot lift
Requirement
When the automatic presser foot lift is activated there should be a clearance of 7 mm bet-
ween the presser foot and the top part of the needle plate.
Move magnet 1 (screw 2) according to the requirement.
Fig. 12 - 24
1
2
74-025
7 mm