Mounting and commissioning the machine
8 - 6
77-014
8.02.05 Mounting the belt guard of the flange motor
Attach belt guard 1 with screws 2 and 3.
Fig. 8 - 08
1
2
3
Fig. 8 - 07
77-012
4
5
7
7
6
Move bearing plate 6 of the motor, so that toothed belt 5 is stretched.
In this position tighten screws 7.
Turn the balance wheel in sewing direction until the needle point descending from above,
is level with the top edge of the needle plate and re-check the value. A tolerance of
± 2 increments is allowed.
Conclude the input.