Input P45 PD2
46
Group
Parameter
Description
User level
Setting range
Set value
4
446
Function of "needle position change" key
1 = needle raised without trimming
2 = needle position change
3 = single stitch
4 = not allocated
5 = tack inversion
6 = tack suppression
B 1 - 6 2
488 Function of F1 key on control panel
1 = needle up without trimming
2 = needle position change
3 = single stitch
4 = single stitch with shortened stitch length
5 = tack inversion
6 = tack suppression
B 1 - 6 1
5
501 Level of presser foot lift at which the speed
reduction starts
(top infl exion point of curve)
B 0 - 255 0
502 Level of presser foot lift at which the mini-
mum speed is reached
(bottom infl exion point of curve)
B 0 - 255 255
522 Needle position at stop during ornamental
tack
ON = raised;
OFF = lowered
B ON - OFFF OFF
523 Tack
ON = ornamental tack (stitch-in-stitch)
OFF = standard tack
A ON - OFF ON
530 Maximum speed for ornamental tack B 300 - 2000 800
538 Tacting output (thread tension release) B 10 - 100 50
584 Tack
ON = quadruple,
OFF = double
B ON - OFF OFF
585 Speed limitation with tack B 300 - 4800 1000