TR-4-9
28 May 2009
FAULT CODE DESCRIPTIONS
TR-017
Fault Code TR-017, indicates that the Outfeed sensor Trimmer (TR-Q6) is faulty.
Initial Actions
Make sure that the Outfeed sensor Trimmer (TR-Q6) is installed correctly.
Procedure
1. Replace sensor TR-Q6.
2. Disconnect plug B.P13 from PCB A. Measure between J13-4 and J13-6 (5V and ground). The voltage is
approximately 5 VDC?
Y N
Replace PCB “A”.
Disconnect plug from sensor TR-Q6. Check wires for Continuity / Short circuit from, the white wire Q6 to
B.P13-5. Is there Continuity and no Short circuit?
Y N
Replace wire Harness.
Connect plug B.P13 to PCB “A”. Measure between the red wire Q6 and the black wire Q6 (5V and ground). The voltage is
approximately 5 VDC?
Y N
Replace wire Harness.
Replace PCB “A”.
TR-016
Fault Code TR-016, indicates that the Control switch infeed (TR-S2) or Control switch outfeed (TR-
S3) is faulty.
Initial Actions
Make sure that the Infeed shaft and the Outfeed compressing bracket is in it’s lower position.
Procedure
Enter the Service mode and select Infeed switch (TR-S2/S3) in check switches. The Infeed switch indicates D:1 activated,
and D:0 deactivated?
Y N
Disconnect the two connectors to switch S2/S3. Measure between the two connectors to switch S2/S3 (5V and
ground). The voltage is approximately 5 VDC?
Y N
Replace PCB “A”.
Replace switch S2/S3.
Replace PCB “A”.