EasyManuals Logo

Polaris ACE 900 XC 2017 User Manual

Polaris ACE 900 XC 2017
512 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #445 background imageLoading...
Page #445 background image
11
9929422 R02 - 2017-2019 ACE 900 Service Manual
© Copyright Polaris Industries Inc.
11.5
ELECTRICAL SERVICE NOTES
Keep the following notes in mind when diagnosing an
electrical problem:
Refer to wiring diagram for stator and electrical
component resistance specifications.
When measuring resistance of a component that has a
resistance value under 10 Ohms, remember to
subtract meter lead resistance from the reading.
Connect the leads together and record the resistance.
The resistance of the component is equal to tested
value minus the lead resistance.
Become familiar with the operation of your meter. Be
sure leads are in the proper jack for the test being
performed (i.e. 10A jack for current readings). Refer to
the Owner’s Manual included with your meter for more
information.
Voltage, amperage, and resistance values included in
this manual are obtained with a Fluke™ 77 Digital
Multimeter (PV-43568). This meter is used when
diagnosing electrical problems. Readings obtained
with other meters may differ.
Pay attention to the prefix on the multimeter reading
(K, M, etc.) and the position of the decimal point.
For resistance readings, isolate the component to be
tested. Disconnect it from the wiring harness or power
supply.
ELECTRICAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris ACE 900 XC 2017 and is the answer not in the manual?

Polaris ACE 900 XC 2017 Specifications

General IconGeneral
BrandPolaris
ModelACE 900 XC 2017
CategoryOffroad Vehicle
LanguageEnglish

Related product manuals