EasyManuals Logo

Polaris GENERAL 2016 User Manual

Polaris GENERAL 2016
690 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #599 background imageLoading...
Page #599 background image
11
9929375 R02 - 2016-2019 GENERAL / GENERAL 4 Service Manual
© Copyright Polaris Industries Inc.
11.47
COMPONENT CONDITION SPN FMI P-CODE
Accelerator Position / Brake
Position Interaction
Condition Exists 520275 31 P150A
Throttle Position Sensor
(1 or 2 Indeterminable)
Neither Position Sensor Passed
Test
520276
12
P150B
Position Sensor Correlation Fault 2 P150C
Throttle Body Control - Power
Stage
Maximum
520277
3 P150D
Minimum 4 P150E
Not Plausible 2 P151A
Signal Error
8 P151B
Deactivated power stages due to
5V sensor supply error
31 P153F
Throttle Body Control - Return
Spring Check Failed
Condition Exists 520278 31 P151C
Throttle Body Control -
Adaptation Aborted
Condition Exists 520279 31 P151D
Throttle Body Control - Limp
Home Position Check Failed
Condition Exists 520280 31 P151E
Throttle Body Control -
Mechanical Stop Adaptation
Failure
Condition Exists 520281 31 P152A
Throttle Body Control -
Repeated Adaptation Failed
Condition Exists 520282 31 P152B
Throttle Body Control
Maximum
520283
3 P152C
Minimum 4 P152D
Outside of Pedal Range (Level 1)
2 P152F
Throttle Body Control -
Position Deviation Fault
Condition Exists 520284 31 P152E
Brake Switch (1 or 2
Indeterminable)
Brake Switch Correlation Fault 520285 2 P153E
ECU Monitoring Error
Condition Exists 520286 31 P1540
ECU Monitoring Error (Level
3)
Condition Exists 520287 31 P1541
ECU Monitoring of Injection
Cut Off (Level 1)
Condition Exists 520288 31 P1542
ECU Monitoring of Injection
Cut Off (Level 2)
Condition Exists 520289 31 P1543
Controller Option Setting Not
Programmed
Out of Calibration 520290 13 P1544
Throttle Body Control -
Requested Throttle Angle Not
Plausible
Condition Exists 520305 31 P1530
ECU Analog to Digital
Converter Fault - No Load
Condition Exists 520306 31 P1531
ECU Analog to Digital
Converter Fault - Voltage
Condition Exists 520307 31 P1532
Accelerator Sensor
Synchronicity Fault Sensor
Difference Exceeds Limit
Condition Exists 520308 31 P1533
ELECTRICAL

Table of Contents