Administrator’s Guide for Polycom HDX Systems
Polycom, Inc. E–4
Require Numbers Off,1,2,All Off Yes Off,1,2,All Off Yes
Require Special Characters Off,1,2,All Off Yes Off,1,2,All Off Yes
Maximum Consecutive Repeated Characters 1-4 2 Yes Off,1-4 Off Yes
Minimum Changed Characters Off,1-4, All Off Yes Off,1-4, All Off Yes
General Settings>Security>Security Banner
Enable Security Banner DoD
Custom
DoD Yes DoD
Custom
DoD Yes
Remote Access Banner Text 10 lines
130 chars/line
DoD Banner
Text
Yes 10 lines
130 chars/line
DoD Banner
Text
Yes
General Settings>Security>Certificates
Always Validate Peer Certificates from Browsers Checkbox Enabled Read Only Checkbox Enabled Yes
Always Validate Peer Certificates from Servers Checkbox Enabled Read Only Checkbox Enabled Yes
General Settings>Security>Whitelist
Enable Whitelist Checkbox Enabled Read Only Checkbox Enabled Yes
General Settings>Security>Account Management
Admin Account/Lock Account after Failed Logins 2-10 3 Yes 2-10 3 Yes
Admin Account/Account Lock Duration in Minutes 1,2,3,5,10,20,30,60,
120,240,480 minutes
1 Yes 1,2,3,5,10,20,30,60,
120,240,480 minutes
1Yes
User Account/Lock Account after Failed Logins 2-10 3 Yes 1-10 3 Yes
User Account/Account Lock Duration in Minutes 1,2,3,5,10,20,30,60,
120,240,480 minutes
1 Yes 1,2,3,5,10,20,30,60,
120,240,480 minutes
1Yes
Failed Login Window
Note: Configurable only through the ‘loginwindowduration’
API command.
Off,1-24 hours Off Yes
(via telnet
command)
Off,1-24 hours Off Yes
Admin Settings Area/Setting
Maximum
(was DoD/DSN)
High
Range
Default
Value
Configurable? Range
Default
Value
Configurable?
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com