The SoundStructure VoIP Interface
12 - 69
Boot Logs
Boot logs show information regarding the boot process of the SoundStructure
VoIP Interface including any firmware updates. The boot log shown next
depicts a system after it has booted up.
App Logs
Application logs show information regarding the application running on the
SoundStructure VoIP Interface. There are different levels of the log informa-
tion that may be viewed by changing the value of the Log Level Filter.
The application logs can provide additional insight into why a line has not reg-
istered successfully. For example, if the authentication user name is not
correct, the log will contain a message as follows:
1117164420|sip |4|00|Registration failed User: 1234, Error Code:404
Not Found
If a the call server is not available or the server IP address is not correct, the log
may contain a message as follows:
1117161439|pmt |4|00|Login failure.
1117161441|sip |4|00|Registration failed User: 200024, Error Code:480
Temporarily not available