Command Protocol Reference Guide
A - 117
Description
This parameter sets the amount of delay applied to the audio signal, in sam-
ples. The sampling frequency is 48 kHz, which means that a sample is 20.83
microseconds. The maximum delay of 96000 samples is equivalent to 2
seconds.
delay_en
Enable Signal Delay
Description
This parameter enables (1) or disables (2) the delay algorithm.
fb_en
Enable Feedback Reduction
Description
This parameter enables (1) or disables (0) the feedback reduction algorithm.
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans
Conferencing Mic/Line Input, Conferencing Line Output,
Sound Reinforcement Mic/Line Input, Sound Reinforcement
Line Output, Analog Telephony Output Submix,
ConferenceLink Aux Input, ConferenceLink Aux Output
Virt Chans Mono, Stereo
Default 0
Event Source No
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans Mono, Stereo
Default 0
Event Source No

Table of Contents

Other manuals for Polycom SoundStructure C12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C12 and is the answer not in the manual?

Polycom SoundStructure C12 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C12
CategoryConference System
LanguageEnglish

Related product manuals