EasyManuals Logo

Polycom SoundStructure C12 User Manual

Polycom SoundStructure C12
712 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #668 background imageLoading...
Page #668 background image
Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 152
dev_temp
Internal Temperature
Description
This parameter returns the temperature (in degrees C) from of one of the inter-
nal temperature sensors. The temperature sensors have the following locations
by index. 1 is at the back right, underneath the plug-in slot. 2 is near the center
of the analog input circuitry. 3 is at the front right, in front of the power supply.
dev_temp_status
Internal Temperature Status
Description
this parameter returns the temperature status of the specified device. If the
internal temperature sensors indicated the device is operating within a safe
temperature rage, the ok value is returned. The warning value is returned when
the temperature is in the marginal temperature range. The error value is
returned when the temperature is in an unsafe temperature range.
Argument Argument value
Channel Type Device-Specific System
Value Type Floating-Point
Read/Write Mode Read-Only
Indices 1-3 : Temperature sensor index
System Limits Minimum: -40.0, Maximum: 125.0, Resolution: 0.1
Event Source No
Argument Argument value
Channel Type Device-Specific System
Value Type List
Read/Write Mode Read-Only
Values
ok : Normal operation
warning : Warning condition
error : Error condition
Event Source Yes

Table of Contents

Other manuals for Polycom SoundStructure C12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C12 and is the answer not in the manual?

Polycom SoundStructure C12 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C12
CategoryConference System
LanguageEnglish

Related product manuals